WARNING: The suppression system will become INOPERATIVE if water is not supplied.
IMPORTANT: Flexible supply (feed) line/coupling must be used. Solenoid valve failure due to hard plumbing
connections will VOID THE WARRANTY. It is recommended that a filter or strainer be
installed in the water supply (feed) line. (For non-tilt models only.)
OPTIONAL MANUAL BYPASS
Provisions are made in the dryer’s suppression system for the installation of an optional manual bypass. Depending on
the model dryer, the connections for the manual bypass are made at the “T” or “four way” fitting located in the outlet
supply side of the water solenoid valve. The use and connections of this manual bypass are at the option or discretion
of the owner.
The water connection for the manual bypass is made to the “T” or “four way” fitting, which has a 3/8” F.P.T. and a
coupling must be used to provide the minimum 1/2” supply (feed) line.
If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold/freezing temperatures,
provisions must be made to protect these water lines from freezing.