c. No air regulation or filtration is provided with the dryer. External regulation/filtration of 80 psi (5.51 bar) must
be provided. It is suggested that a filter/regulator/gauge arrangement be added to the compressed air line just
before the dryer connection. This is necessary to ensure that correct and clean air pressure is achieved.
5. Steam Damper System Operation
The steam damper, as shown in the illustration below, allows the coil to stay constantly charged eliminating
repeated expansion and contraction. When the damper is opened, the air immediately passes through the already
hot coil, providing instant heat to start the drying process. When the damper is closed, ambient air is drawn
directly into the basket (tumbler), allowing a rapid cool down.
Diagram 1 – shows the damper in the heating (open) mode, allowing heat into the basket (tumbler).
Diagram 2 – shows the damper in the cool down (closed) mode, pulling ambient air directly into the basket
(tumbler) without passing through the coils.
NOTE: With the dryer off or with no air supply, the damper is in the cool down mode as shown in Diagram 2.
NOTE: Turning knob on flow control clockwise (CW) will restrict airflow. Turning knob
counterclockwise (CCW) will allow higher airflow.