Remove lint accumulation from around the openings in the dryer’s back panels.
Remove lint from gas valve burner train area with a dusting brush or vacuum cleaner attachment.
Remove any lint accumulation from coin acceptor area, including the optical switch.
Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from the dryer’s
internal exhaust ducting.
WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCTWORK CAN
CREATE A POTENTIAL FIRE HAZARD.
Clean the steam coil fins (or filters). We suggest using compressed air and a vacuum cleaner with brush
attachment.
NOTE: When cleaning steam coil fins, be careful not to bend the fins. If fins are bent, straighten by
using a fin comb, which is available from local air conditioning supply houses.
6 MONTHS
In the cleaning of the dryer’s cabinet, avoid using harsh abrasives. A product for the cleaning of appliances is
recommended.
ALL bearings and setscrews should be checked to insure that they are tight.
B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws (bearing setscrews), grounding connections, nonpermanent gas connections, (unions,
shutoff valves, and orifices) and electrical terminations. The 12-Rib 95” (J) poly belt arrangement should be
examined. A cracked or seriously frayed belt(s) should be replaced. Tighten loose belt(s) when necessary and
check the alignment. Complete operational check of controls and valves. Complete operational check of
ALL
safety devices (door switches, lint compartment switches, sail switches, and burner and hi-limit thermostats).
C. LUBRICATION
The motor bearings, idler bearings, and basket (tumbler) bearings are permanently lubricated. No lubrication is