American Dryer Corp. AD-30 Clothes Dryer User Manual


 
6 American Dryer Corp. 450268-1
6 MONTHS
Inspect and remove lint accumulation in the customer furnished exhaust ductwork system. Inspect exhaust
draft dampers to ensure they are not binding. Inspect and remove ALL lint accumulation from in and
around control box area including coin acceptors. Clean lint accumulation from around tumbler wrapper
area.
IMPORTANT: THE ACCUMULATION OF LINT IN THE EXHAUST DUCTWORK CAN
CREATE A POTENTIAL FIRE HAZARD.
AS REQUIRED
In the cleaning and care of the cabinet, avoid using harsh abrasives. A product intended for the cleaning
of appliances is recommended.
B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws (bearing setscrews), nonpermanent gas connections, and grounding
connections (unions, shutoff valves, and orifices). Motor and drive belts should be examined. Cracked
or seriously frayed belts should be replaced. Tighten loose V-belts when necessary, and check belt
alignment. Complete operational check of controls and valves. Complete operational check of ALL
safety devices (door switches, sail switch, burner and lint chamber thermostats).
NOTE: V-belts
should be
replaced in matched pairs.
C. LUBRICATION
The motor bearings, idler bearings and tumbler bearings are permanently lubricated, and no lubrication
is necessary.