American Dryer Corp. AD-25V Clothes Dryer User Manual


 
8 American Dryer Corp. 113237-4
!
!
!
!
!
!
!
Provisions for adequate air supply must be provided as noted
in this manual (refer to Fresh Air Supply Requirements).
Clearance provisions must be made from noncombustible
construction as noted in this manual (refer to Dryer Enclosure
Requirements).
Provisions must be made for adequate clearances for servicing
and for operation as noted in this manual (refer to Dryer
Enclosure Requirements).
Dryer must be exhausted to the outdoors as noted in this
manual (refer to Exhaust Requirements).
Dryer must be located in an area where correct exhaust venting
can be achieved as noted in this manual (refer to Exhaust
Requirements).
Important
Dryer should be located where a minimum amount
of exhaust duct will be necessary.
The dryer must be installed with a proper exhaust duct
connection to the outside.
The dryer must be installed with provisions for adequate
combustion and make-up air supply.
Caution
This dryer produces combustible lint and must be
exhausted to the outdoors. Every 6 months,
inspect the exhaust ducting and remove any lint buildup.
Important
Dryer must be installed in a location/environment,
which the ambient temperature remains between
40º F (4.44º C) and 130º F (54.44º C).
Dryer Enclosure Requirements _______
Bulkheads and partitions should be made of noncombustible
materials and must be located a minimum of 12-inches (30.48
cm) above the dryer’s outer top; 18-inches (45.72 cm) for
steam dryers, except along the front of the dryer, which may
be closed if desired.
Note
Allowances must be made for opening the control
door.
Installation Procedures _______________
Installation should be performed by competent technicians in
accordance with local and state codes. In the absence of
these codes, the installation must conform to applicable
American National Standards: ANSI Z223.1-LATEST EDITION
(National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST
EDITION (National Electrical Code) or in Canada, the
installation must conform to applicable Canadian Standards:
CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-
M91 (L.P. Gas) or LATEST EDITION (for General Installation
and Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2
CSA C22.1-1990 or LATEST EDITION (for Electrical
Connections).
Unpacking/Setting Up _________________
Remove protective shipping material (i.e., plastic wrap and
optional shipping box) from dryer.
Important
Dryer must be transported and handled in an
upright position at all times.
The dryer can be moved to its final location while still attached
to the skid or with the skid removed. To unskid the dryer,
locate and remove the four bolts securing the base of the
dryer to the wooden skid. Two are at the rear base (remove
the back panel for access), and two are located in the bottom
of the lint chamber. To remove the two bolts located in the lint
chamber area, remove the lint door.
With the skid removed, to make it easier to slide the dryer
into its final position, slightly lower all four leveling legs, so
that the dryer will slide on the legs instead of the base frame.
Leveling Dryer
The dryer is equipped with four leveling legs, one at each
corner of the base. Two are located at the rear of the dryer
base, and two are located in the lint chamber (coop). To
increase bearing life and improve efficiency, the dryer should
be tilted slightly to the rear.
Location Requirements _______________
Before installing the dryer, be sure the location conforms to
local codes and ordinances. In the absence of such codes or
ordinances the location must conform with the National Fuel
Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada, the
installation must conform to applicable Canadian Standards:
CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-
M91 (L.P. Gas) or LATEST EDITION (for General Installation
and Gas Plumbing).
The dryer must be installed on a sound level floor capable of
supporting its weight. Carpeting must be removed from the
floor area that the dryer is to rest on.
Important
“The dryer must be installed on noncombustible
floors only.”
The dryer must not be installed or stored in an area where it
will be exposed to water and/or weather.
The dryer is for use in noncombustible locations.
X = 12-inch (30.48 cm) minimum, 24-inches (60.96 cm) is suggested for ease
of maintenance.
* 1-inch (2.54 cm) maximum for electric dryers.
**18-inch (45.72 cm) minimum for steam dryers.
Note
Air considerations are important for proper and
efficient operation.