American Dryer Corp. AD-25 Clothes Dryer User Manual


 
20 American Dryer Corp. 450268-1
B. BURNER CONTROLS (GAS)
This illustration is typical of ALL gas burners, but they are not ALL exactly alike. Your particular model
may have some differences.
TO REPLACE SPARK IGNITOR
1. Discontinue power to the dryer.
2. Disconnect high voltage connector and flame-probe
connection from ignitor.
3. Disassemble ignitor from burner by removing the two
(2) self-tapping screws.
4. Reverse procedure for installing the new ignitor probe.
NOTE: Before reestablishing power to the dryer,
visually check the following: (refer to the
illustration).
5. The flame-probe, ignitor probe, and ground rod are ALL
on the same line of axis.
6. There should be a 1/8” gap (+/- 1/32) between the ignitor probe and ground rod.
7. DO NOT wrap the red high voltage wire and flame-probe wire together. (Improper operation may
result.) They may run along side each other.