© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
19
802702
3. Remove ground screw and save for use in Step 5.
Remove wire and use in Step 6.
Figure 16
4. Use a strain relief and insert end of power cord
through power supply hole.
Figure 17
5. Attach power cord ground (green) wire to rear
bulkhead using ground screw removed in Step 3.
Figure 18
6. Use the three screws from the accessories bag to
attach the remaining power cord wires to the
terminal block as follows:
a. Red wire to “L1” terminal.
b. Black wire to “L2” terminal.
c. White wire to Neutral terminal.
NOTE: When installing the white wire, loop the
free eyelet end of the ground wire (removed in
Step 3) and attach along with the white wire to the
neutral (center) terminal on the terminal block.
7. Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws
firmly may result in wire failure at the terminal
block.
8. Secure the strain relief to the power cord, or
wires, where they enter the dryer cabinet.
9. Check the continuity of the ground connection
before plugging the cord into an outlet. Use an
acceptable indicating device connected to the
center grounding pin of the plug and the green
screw on the back of the cabinet.
10. Reinstall access cover and screw.
D697I
1 Ground Screw
D696I
D697I
1
DRY1920N
1 White
2 “L2” Terminal
3 Black
4 Green
5 Red
6 Neutral Terminal
7 “L1” Terminal
DRY1920N
5
7
1
2
4
6
3