Maintenance
62
F232062
Monthly
(Continued)
c. For flat-pulley drive systems, verify
allowable distance of belt from edge of
pulley as shown in chart below:
d.
For 3-speed and variable-speed
models only,
verify that V belts are
properly tensioned by applying a set
force to the belt and measuring the
deflection to determine the belt tension.
See the tables below for the acceptable
belt tension ranges. Belt tension
measurements should be taken as close
to the center of the belt span as
possible. See Figure 51.
3. Remove back panel and check overflow
hose and drain hose for leaks.
4. Unlock the hinged lid and check the
supply dispenser hoses and
hose connections.
Figure 51
Cabinet Hardmount
Flat Pulley Alignment
Model
Allowable
Distance from
Edge (in.)
18 3/32
27 3/32
35 3/32
50 3/8
H039IE1A
Deflection
Span
Length