17
Installation
F232062
Drive Train Information
Number of motors in drive train 1 2 2 2
Wash/reverse power, hp (kW) 0.18 (0.13) 0.40 (0.30) 0.90 ( 0.67) 1.0 (0.75)
Medium extract power, hp (kW) 1.2 (0.895) 0.45 (0.34) 1.0 (0.75) 1.2 (0.89)
High extract power, hp (kW) 1.5 (1.12) 3.0 (2.2) 3.5 (2.6) 4.5 (3.36)
Cylinder Speeds
Wash/reverse speed, rpm 46 47 44 40
Medium extract speed, rpm 330 75 60 64
High extract speed, rpm 661 591 561 530
Centrifugal Force Data
Wash/reverse centrifugal force, Gs 0.65 0.82 0.825 0.82
Medium extract centrifugal force, Gs 32.5 2.10 1.53 2.1
High extract centrifugal force, Gs 130 130 134 143
Balance Detection
Vibration safety switch installed N/A Standard Standard Standard
Direct Steam Heating (Optional)
Steam inlet connection size, in (mm) 1/2 (13) 1/2 (13) 1/2 (13) 1/2 (13)
Number of steam inlets 1 1 1 1
Steam req. to raise bath
temperature 10°F, lb
(10°C, kg)
LOW 1.1 (0.5) 2.1 (0.95) 2.8 (1.3) 4.4 (2.0)
HIGH 1.2 (0.54) 2.8 (1.3) 3.7 (1.7) 6.3 (2.9)
Average steam use per cycle, BHP 0.66 1.4 1.9 3.1
Electrical Heating (Optional)
Total electrical heating capacity, kW 7.8 15.6 23.4 31.2
Electrical heating elements 3 6 9 12
Electrical heat element size, kW 2.6 2.6 2.6 2.6
Cabinet Hardmount General Specifications
3-Speed Models (Continued)
Specification 18355080