43
Installation
F232062
Before any deviation from specified
installation procedures is attempted,
the customer or installer should contact
the distributor.
Increasing the drain hose length, installing
elbows, or causing bends will decrease drain
flow rates and increase drain times, impairing
machine performance.
See the Cabinet Hardmount Drain Information
table in this subsection for capacity-specific
drain information.
Installation of additional machines will require
proportionately larger drain connections. See
the Cabinet Hardmount Drain Line Sizing
table in this subsection.
Cabinet Hardmount
Drain Information
18 25 27 35 50 80
Drain connection size, ID, in (mm) 2 (52) 2 (52) 2 (52) 2 (52) 3 (76) 3 (76)
Number of drain outlets 111111
Drain flow capacity, gal-min (l-min) 20 (76) 25 (95) 25 (95) 35 (132) 50 (189) 50 (189)
Recommended drain pit size, ft
3
(l)
1.80 (51) 2.36 (66.8) 2.50 (70.3) 3.14 (88.9) 4.52 (128) 5.90 (169)
Cabinet Hardmount
Drain Line Sizing
Minimum Drain I.D. [in (mm)]
Model
Number Of Machines
12345
18 2 (51) 3 (76) 3 (76) 4 (102) 4 (102)
25 2 (51) 3 (76) 3 (76) 4 (102) 4 (102)
27 2 (51) 3 (76) 3 (76) 4 (102) 4 (102)
35 3 (76) 3 (76) 3-1/2 (89) 4 (102) 4 (102)
50 3 (76) 4 (102) 6 (152) 6 (152) 6 (152)
80 4 (102) 6 (152) 6 (152) 8 (203) 8 ( 203)