Alliance Laundry Systems D677I Clothes Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
512682
24
Vending
Meter Case
(Metered Models)
The factory mounted coin meter case does not include
the service door lock, coin drawer, coin drawer lock
and keys. These parts must be ordered (at extra cost)
according to the purchaser’s requirements direct from
the manufacturer of your choice.
NOTE: You have the option of using a screw type
lock or a 1/4 turn lock on the meter case service
door. If you choose to use a screw lock, then the
special bracket (located inside the meter case) must
be used. DO NOT use the special bracket if a
1/4 turn lock is used.
Coin Drawer Security – for additional security, drill
out the two pilot holes on each front side of the meter
case to 6.4 or 8.0 mm (1/4 or 5/16 inch) holes and
install a bicycle lock through these holes.
Coin Slide Control
(Coin Slide Models Only)
Power-Up Mode
When power is applied to the dryer, the control will
enter the Ready Mode. If the control was powered
down during a running a cycle, the IN USE LED will
flash once and the control will enter Start Mode. If the
dry time dipswitch settings have not been changed
from factory default, the IN USE LED will flash once.
Ready Mode
In Ready Mode, the control waits for the vend to be
satisfied before entering Start Mode.
Start Mode
In Start Mode, the vend has been satisfied, but the
Start button has not been pressed. The IN USE LED
will be lit. The timer will not count down until the
Start button is pressed.
Run Mode
In Run Mode, the control is running a cycle. The
IN USE LED is lit.
Door Open Mode
In Door Open Mode, the control turns off the heater
and motor when the door is opened during a run cycle.
The timer will continue to count down time and the
IN USE LED is lit.
End of Cycle Mode
In End of Cycle Mode, a cycle is complete and the
IN USE LED is off. The control remains in this mode
until the door is opened or additional vend has been
satisfied.
Topoffs
Any time the control receives a coin slide pulse during
a cycle it will add the programmed dry time to the time
currently remaining in the cycle. The IN USE LED
will flash briefly to indicate the coin input. The
maximum cycle time is 99 minutes. The control will
not add time beyond 99 minutes. The cool down time
will not change. If the control receives a coin slide
pulse during cool down it will exit cool down and start
heating with the cycle time equal to the programmed
time.
Temperature Selector Switch
For five minutes after the control is powered up, there
is a diagnostic feature that allows the temperature
selector switches to be tested. When the temperature
selector is changed, the new setting is displayed by
flashing the IN USE LED as follows:
High/Normal: 4 flashes
Medium/PP: 3 flashes
Low/Delicate: 2 flashes
No Heat: 1 flash