504523 27
Manufactured (Mobile) Home
Installation . . .
The dryer can be installed in a manufactured (mobile)
home by following these instructions:
1. IMPORTANT: Gas dryers MUST be
permanently attached to the floor at the time of
installation. Order No. 526P3 Dryer Installation
Kit for a manufactured (mobile) home
installation. Follow the instructions supplied with
the kit.
2. Venting—Dryer MUST be exhausted to the outdoors.
The dryer can be exhausted to the outdoors through
the back, left, right or bottom panel. Gas dryers
cannot be exhausted out the left side because of the
burner housing.
Exhaust duct must be secured to the mobile home
structure.
Exhaust ducts MUST NOT be connected with sheet
metal screws or fasteners which extend into the duct.
Exhaust duct MUST NOT be connected to any other
duct, vent or chimney.
Dryer exhaust MUST NOT terminate under the
mobile home.
For proper operation, it is important that the dryer has
an ample amount of outside make-up air. The free area
of any opening for the introduction of outside air must
be at least 163 cm
2
(25 in
2
).
When exhausting the dryer to the outdoors, the dryer
can be installed with “0” inch clearance at the sides
and rear. Clearance of the duct from combustible
construction must be a minimum of 5.1 cm (2 inches).
Venting materials are not supplied with the dryer
(obtain locally).
IMPORTANT: Installation must conform to
the Manufactured Home Construction and
Safety Standards, Title 24 CFR, Part 32-80 or
Standard CAN/CSA-Z240 MH.
To reduce the risk of fire and combustion gas
accumulation, the dryer MUST BE
EXHAUSTED TO THE OUTDOORS. Refer to
Section on Dryer Exhaust Requirements.
W047
WARNING
To reduce the risk of fire, the exhaust duct
and weather hood MUST be fabricated of a
material that will not support combustion.
Rigid or flexible metal pipe is recommended
for a clothes dryer.
W048
WARNING