Sterling SCD 10 Clothes Dryer User Manual


 
10 CFM Compressed Air Dryer Chapter 5: Maintenance 22 of 30
5-3 Replacing the Fuse Outside of the Cabinet
Note: If the compressed air dryer does not start when the ON/OFF switch is in the
“ON” position, check the main power supply to ensure that it is properly installed. If
the main power supply is correct, check the fuse. This is located on the front of the
driver cabinet. Use the following procedure to check and, if needed, replace the fuse.
1. Make sure that the main power to the dryer is shut off and locked out.
2. Locate the fuse holder that houses the fuse for the dryer (see picture below for fuse
holder location).
3. Using a standard flat-head screwdriver, remove the insert that holds the fuse from the
fuse holder.
4. Separate the insert from the fuse.
5. Using a multimeter, check for continuity between the two ends of the fuse.
6. If there is no continuity, replace the fuse. See Spare Parts List for fuse part number.
7. Insert new fuse into the fuse holder.
8. Using a standard flat-head screwdriver, turn the fuse into the installed position within
the fuse holder.
Fuse Holder