Sterling 882.00290.00 Clothes Dryer User Manual


 
Entering Operating Parameters to Select Modes
To enter the display:
1. Press both the Up
and Down keys for three seconds from the home page. The word
SEE will appear in the upper display and PAGE will appear in the lower display.
2. Press the Advance Key
to move through the parameter prompts.
3. Press the Up
or Down keys to change the parameter value.
4. Press the RESET Key at any time to return to the Home Page display.
Figure 9: Setting List for Redundant Safety Controller (WATLOW), Part No. A0568961
Mode Parameter Setting range Default Manf. setting
SEn Sensor Type 0-3 0 -
Lin Thermocouple Linearization 0-10 0 H (1)
C-F Temperature Units Fahrenheit / Celsius F -
S.dEC Temp. Decimal Places 0 – 0.0 0 -
IS.En INFOSENSE™ Yes / No No -
Sc.Lo Process Scale Low 4.00 to 20.00 mA
1.00 to 10.00V
4.00 mA
1.00V
0
Sc.hi Process Scale High 4.00 to 20.00 mA
1.00 to 10.00V
20.00 mA
5.00 V
400
CAL Calibration Offset -999 to 999 0 -
Ftr.E Input Filter Off, DiSP, Cont, both OFF -
Ot 1 Output 1 Function Limit (2) (2) -
LSd1 Output 1 Limit Sides Both, High, Low Both High
hyS1 Limit 1 Hysteresis 0.0 to 999.0 1.0 -
Ot2 Output 2 Function Off / Process Alarm / Limit (2) OFF -
LSd2 Output 2 Sides Both / high / low Both -
UdSP Upper Display Look
None, Process Value, Limit 1 Low Set,
Limit 1 High Set, Limit 2 Low Set, Limit
2 High Set, Alarm 2 Low Set, Alarm 2
High Set, Limit 3 Low Set, Limit 3 High
Set, Alarm 3 Low Set, Alarm 3 High Set
Process -
LdSP Lower Display Look
None, Process Value, Limit 1 Low Set,
Limit 1 High Set, Limit 2 Low Set, Limit
2 High Set, Alarm 2 Low Set, Alarm 2
High Set, Limit 3 Low Set, Limit 3 High
Set, Alarm 3 Low Set, Alarm 3 High Set
Limit 1
High Set
-
LOC Lockout
(0) no lockout, (1) Programming and
Setup Page Locked, (2) Limit Set
Points are the only Operation Page
parameters accesible, (3) Full Lockout.
0 2
Dehumidifying Dryers Chapter 4: Operation 27 of 53