Sterling 882.00290.00 Clothes Dryer User Manual


 
Redundant Safety Controller Display
Optional
The Redundant Safety Controller limits the process air temperature from exceeding the upper
temperature range set by the E5CN Temperature Controller. Standard dryers use a
microprocessor-based controller for limiting the process air temperature. The controller is a
modular, self-contained unit removable from the mounting housing. All parameters are
factory set and adjusted; normally, no field adjustment to the internal controls are necessary.
Figure 8: Typical Redundant Safety Controller Display; Part No. A0568961
Setting the Redundant Safety Controller
The Redundant Safety Controller alarm setting is changed by pressing the up and down keys
to input the alarm value. The upper display reading indicates the Process Value, while the
lower display indicates the High Point Setting alarm value. The factory setting for the High
Point Alarm Value
(L1-hi ) is 150°F (-23°C).
Restoring the WATLOW Redundant Safety Controller to Factory Setup
If the preset parameters on the controller have been tampered with and it no longer functions
properly, see page 28 for Factory Default. This controller is not meant to be modified.
WATLOW Operating Parameters
The
WATLOW controller has only one mode selection; ALARM.
The factory sets the security level to protect the critical parameters from being accidentally
changed. Below is an explanation of the modes you will have access to and the manufacturer
default settings.
Dehumidifying Dryers Chapter 4: Operation 26 of 53