Maytag W10201175A Clothes Dryer User Manual


 
24
Dryer Results
Clothes are not drying satisfactorily, drying times are too long, or load is too hot
Is the lint screen clogged with lint?
Lint screen should be cleaned before each load.
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
Is the exhaust vent or outside exhaust hood clogged with lint, restricting air movement?
Run the dryer for 5-10 minutes. Hold your hand under the outside exhaust hood to check
air
movement. If you do not feel air movement, clean exhaust system of lint or replace
exhaust vent with heavy metal or flexible metal vent. See the Installation Instructions.
Are fabric softener sheets blocking the grille?
Use only one fabric softener sheet, and use it only once.
Is the exhaust vent the correct length?
Check that the exhaust vent is not
too long or has too many turns. Long venting will
increase drying times. See the Installation Instructions.
Is the exhaust vent diameter the correct size?
Use 4" (10.2 cm) diameter vent material.
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
Is the dryer located in a room with temperature below 45ºF (7ºC)?
Proper operation of dryer cycles requires temper
atures above 45ºF (7ºC).
Is the dryer located in a closet?
Closet doors must have ventilation
openings at the top and bottom of the door. The rear of
the dryer requires 5" (12.7 cm) of airspace, and the sides and
front of the dryer require a
minimum of 1" (2.5 cm). See the Installat
ion Instructions.
Has the Air Fluff modifier been selected?
Select the right temperature for the types of garments
being dried. See “Modifiers.”
Is the load too large and heavy to dry quickly?
Separate the load to tumble freely.
Are clothes coming out of the Rapid Refresh Small Load cycle with damp or wet spots?
Under certain environmental or installation conditions, y
ou may experience underdrying.
Select the CUSTOM REFRESH cycle (20 min. default time), which can be customized by
selecting the temper
ature by pressing TEMP LEVEL and/or cycle time by pressing the TIME
ADJUST + (plus) or – (minus).