9
Electrical connection
Any electrical work required to install this appliance should
be carried out by a qualified electrician or competent per-
son.
1 WARNING – THIS APPLIANCE MUST BE
EARTHED.
Should the appliance power supply cable need
to be replaced, this must be carried out by a
Service Force agent (see page 23).
The manufacturer declines any liability should
these safety measures not be observed.
Before switching on, make sure the electricity supply voltage
is the same as that indicated on the appliance rating plate
(See picture on page 5).
The appliance is supplied with a 13 amp plug fitted. In the
event of having to change the fuse in the plug supplied, a
13 amp ASTA approved (BS 1363/A) fuse must be used.
Should the plug need to be replaced for any reason, pro-
ceed as described below.
The wires in the mains lead are coloured in accordance with
the following code:
If you fit your own plug, the colours of the wires in the
mains lead of your appliance may not correspond with the
markings identifying the terminals in your plug.
Proceed as follows:
1.Connect the Green and Yellow (earth) wire to the termi-
nal in the plug which is marked with the letter “E“ or by
the earth symbol E or coloured green and yellow.
2.Connect the Blue (neutral) wire to the terminal in the
plug which is marked with the letter “N“ or coloured
black.
3.Connect the Brown (live) wire to the terminal in the plug
which is marked with the letter “L“ or coloured red.
4.Upon completion there must be no cut, or stray strands
of wire present and the cord clamp must be secure over
the outer sheath.
1 WARNING!
A cut off plug inserted into a 13 amp socket is
a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of safely.
1 The plug must still be accessible after the ap-
pliance has been installed.
1 The appliance should not be connected to the
electrical supply by means of an extension ca-
ble.
Permanent Connection
In the case of a permanent connection it is necessary that
you install a double pole switch between the appliance and
the electricity supply (mains), with a minimum gap of 3mm
between the switch contacts and of a type suitable for the
required load in compliance with the current electrical reg-
ulations.
The switch must not break the yellow and green earth cable
at any point.
Green and Yellow: Earth
Blue: Neutral
Brown: Live