John Lewis JLBIWM1401 Washer/Dryer User Manual


 
11
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
The manufacturer declines any liability
should this safety measure not be
observed.
Should the appliance power supply
cableneed to be replaced, this must be
carriedout by a Service Force agent (see
page 28).
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance’s
rating plate. The rating plate is located at the top of the
rim of the open door.
The appliance is supplied with a 13amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 13amp ASTA approved (BS1363/A) fuse
must be used.
Should the plug need to be replaced for any reason,
proceed as described below.
The wires in the mains lead are coloured in accordance
with the following code:
Green and Yellow - Earth
Blue - Neutral
Brown - Live
If you fit your own plug, the colours of the wires in
themains lead of your appliance may not correspond
with themarkings identifying the terminals in your
plug.
Proceed as follows:
1.The wire coloured green and yellow must be
connected to the terminal marked with the letter
«E» or by the earth symbol or coloured green
and yellow.
GREEN & YELLOW
BROWN
CORD CLAMP
BLUE
13A
P1041
E
N
L
2.The wire coloured blue must be connected to the
terminal marked «N» or coloured black.
3.The wire coloured brown must be connected to the
terminal marked «L» or coloured red.
4.Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.
WARNING:
A cut off plug inserted into a 13 amp
socket is a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safely.
The power supply cable must be easily
accessible after installing the appliance.
The appliance should not be connected to
the electrical supply by means of
anextension cable
Permanent connection
In the case of permanent connection it is necessary
that you install a double pole switch between the
appliance and the electricity supply (mains), with a
minimum gap of 3mm between the switch contacts and
of a type suitable for the required load in compliance
with the current electrical regulations.
The switch must not break the yellow and green earth
cable at any point.
Electrical connection