GSI Outdoors PNEG-552 Clothes Dryer User Manual


 
22 PNEG-552 100 Series Dryer
5. Dryer Pre-Start Checks
Before the dryer is filled, thoroughly inspect the unit and check the operation of the dryer as follows.
Inspect the Metering Rolls
Figure 5A Asco Safety Shut Off Valve
Open all metering roll access doors and inspect each compartment for any bolts, nuts or other foreign
material, that may cause possible jamming of the metering rolls.
Set Control Switches
Moisture Control Switch OFF
Moisture Control Thermostat 200°
Load Switch OFF
Unload Switch OFF
Fan Switch OFF
Burner Switch OFF
Out of Grain Timer 1 MINUTE (Reset to 8 Minutes after testing)
Load Delay 30 SECONDS
Unload Delay 30 SECONDS
Metering Roll Speed LOW AND HIGH SPEED SETTINGS PUT ON ZERO
Dry Timer 60 MINUTES
Cool Timer 20 MINUTES
Unload Timer 10 MINUTES
Mode Switch CONTINUOUS FLOW
Before attempting to operate the dryer make sure all safety shields are in place,
all bottom clean-out and rear access doors are closed and all personnel are
clear of the dryer.