(ISO conditions - natural gas - electrical generator terminals)
ISO RATED HEAT RATE EFFIC. PRESSURE EXHAUST TURBINE EXHAUST
POWER RATIO FLOW SPEED TEMPERATURE
kW kJ/kWh % kg/sec Ibs/sec RPM °C °F
PGT5 5,220 13,422 26.8 9.1 24.6 54.2 10,290 523 973
GE5 5,500 11,740 30.7 14.8 19.6 43.1 16,630 574 1,065
PGT10 10,220 11,540 31.2 13.8 42.3 93.3 7,900 488 910
GE10 11,250 11,481 31.4 15.5 47.5 104.7 11,000 482 900
PGT16 13,720 10,300 35.0 20.2 47.3 104.3 7,900 491 919
PGT20 17,464 10,238 35.2 15.7 62.5 137.7 6,500 475 887
PGT25 22,417 9,919 36.3 17.9 68.9 151.9 6,500 525 976
PGT25+ 30,226 9,084 39.6 21.6 84.3 185.9 6,100 500 931
LM6000 42,703 8,770 41.0 27.9 125.8 288.8 3,600 452 840
MS5001 26,830 12,687 28.4 10.5 125.2 276.1 5,094 483 901
MS5002E 31,100 10,285 35.0 17.0 102.0 225.0 5,714 511 952
MS6001B 42,100 11,230 32.1 12.2 141.1 311.0 5,163 548 1,026
MS7001EA 85,400 10,990 32.7 12.6 292.0 643.0 3,600 537 998
MS9001E 126,100 10,650 33.8 12.6 418.0 921.0 3,000 543 1,009