34
Solutions to Common Problems
Service Prevention Checklist
Beforecallingforservice,reviewthislist.Itmaysavebothtimeandexpense.Thelistincludescommon
occurrencesthatarenottheresultofdefectiveworkmanshipormaterialsinthisdryer.
OCCURRENCE POSSIBLECAUSE SOLUTION
Dryerdoesnotstart. Electricalpowercordisnotsecurelyplugged
inorplugmaybeloose.
Makesuretheplugtstightlyinwalloutlet.
Housefuseblownorcircuitbreakertripped. Resetcircuitbreakerorreplacefuse.
Makesureelectricallineisnotoverloadedandthe
dryerisonaseparatecircuit.
Thermal limiter tripped. Callauthorizedservicepersonforreplacement.
LCDdisplays
DEMO MODE.
Dryerhasbeenprogrammedtotemporarily
performarepeatingdemocycle.
Toreturntothefactorydefaultsettings,selectRESET
in set prefs under the optionsscrollbuttons.
Dryerrunsbutwon’t
heat.
Thereare2housefusesinthedryercircuit.If1
ofthe2fusesisblown,thedrummayturnbut
theheaterwillnotoperate.(electricmodels)
Replace fuse.
Gassupplyvalveisnotopen(gasmodels). Checktomakesuresupplyvalveisopen.SeeINSTAL-
LATIONINSTRUCTIONSforprocedure.
Dryerdoesnothaveenoughairsupplyto
supporttheburnerame(gasmodels).
SeeINSTALLATIONINSTRUCTIONS.
LPgassupplytankisemptyortherehas
beenautilityinterruptionofnaturalgas(gas
models).
Rellorreplacetank.
Dryershouldheatwhenutilityserviceisrestored.
Dryingcycletakestoo
long, outside of the
dryerfeelstoohotor
smells hot.
Lintlteriscloggedwithlint. Makesurealllinthasbeenremovedfromthedryerlint
lterbeforestartingeachcycle.
Exhaustductrequirementshavenotbeen
met.
Exhaustductmustbeatleast4inchesindiameterand
made of rigid or semi-rigid metal.
When in place, the duct must have no more than
two90°bendsandmustnotexceedlengthlistedin
INSTALLATIONINSTRUCTIONS.
Electricdryerisconnectedtoa208volt
circuit.
Dryingtimewillbe20%longerthandryingona240
volt circuit.
Dryingprocedureshavenotbeenfollowed. See“OperatingInstructions.”
Outsideexhausthoodorexhaustductmay
becloggedorrestricted.
Cleanoutanyobstruction.
Highhumidity. Useadehumidiernearthedryer.