12
Installation Instructions
Electrical connection (non-Canada) - 3 wire cord
Turn off power supply to outlet. 1.
Remove the screw securing the terminal block 2.
access cover in the lower corner on the back of
the dryer.
Install a UL-approved strain relief according 3.
to the power cord/strain relief manufacturer’s
instructions in the power cord entry hole below
the access panel. At this time, the strain relief
should be loosely in place.
ThreadanUNPLUGGED,UL-approved,30amp.4.
powercord,NEMA10-30typeSRDT,throughthe
strain relief.
Attachthepowercordneutral(centerwire)5.
conductor to the SILVER colored center
terminal on the terminal block. Tighten the
screw securely.
Attach the remaining two power cord outer 6.
conductorstotheouter,BRASScolored
terminals on the terminal block. Tighten both
screws securely.
WARNING
ELECTRICALSHOCKHAZARD
Do not make a sharp bend or crimp wiring/
conductor at connections.
3-wire receptacle
(NEMAtype10-30R)
Internal ground
(GREEN screw)
Install
UL-approved
strain relief here
Terminal screw
recovery slot
Line 1
(BRASS terminal)
Neutral
(SILVER terminal)
Line 2
(BRASS terminal)
Access cover
screw
Terminal
block
Neutral
(center wire)
30 AMP
NEMA 10-30
NOTE
If a terminal screw falls during cord installation,
it can be retrieved in the terminal screw recovery
slot below the access panel.
WARNING
ELECTRICALSHOCKHAZARD
Failure to disconnect power source before servicing
couldresultinpersonalinjuryorevendeath.
Follow manufacturer’s guidelines for firmly 7.
securing the strain relief and power cord.
Reinstall the terminal block cover.8.
DO NOT remove
internal ground in
a 3-wire system!!
Neutral
terminal
IMPORTANT
If moving dryer from a 4-wire system and
installing it in a 3-wire system, move the internal
ground from the center terminal back to the
GREENscrewnexttotheterminalblock.