Dyson CRO2 Washer User Manual


 
Water supply
Drainage
Installation
Connect your machine to the water supply by hand, using the
hoses supplied. Only tighten by hand, do not use a spanner.
Do not use old hoses.
Ensure the water pressure is between 0.4 and 5 bar.
Do not:
connect the machine to a mixer tap.
Hot and cold water supply
Attach the blue inlet hose to the cold inlet tap and the red
hose to the hot inlet tap, and turn on water supply.
5 02
You can alter the direction of the drainage hose to the left
or right.
•To change the direction of the machine’s drainage hose,
squeeze open the retaining clip using a pair of pliers and
hold it open while you rotate the hose.
Ensure the hose is inserted properly before releasing the clip.
Thread the drainage hose through the hose hook and adjust
the protruding end to a distance of 30mm. The hose hook
has a small retention hole that can be used to secure the
hose in position.
Do not use the hose hook for under-sink connections.
When installed with a standpipe or under-sink connection,
ensure that the water outlet end of the drainage hose is no
lower than 450mm above ground level. Position the hose so
that none of it lies higher than 600mm above ground level
(refer to section 01 for position).
NB: Failure to comply with these dimensions could cause
the machine to malfunction.
5
*Note: CRO1 Flowcheck and Memory have grey leak protection inlet hoses
Drainage hose hook
Drainage hose
30mm
Stand pipe
8887_CRO2_OPS_INNERS.qxd 5/11/03 3:26 pm Page 7