Ensure the
machine
is plugged in and
switched on. Check the fuse and also
that the circuit breaker has not tripped.
(See
section 02)
for the programme
options wash table.
Wait for the machine to finish the cycle
before opening the door. To cancel the
wash hold down the
‘Cancel’
button.
Press ‘Start’ to resume the wash.
Hold down the
‘Minimum iron’
button until
‘Child lock off’ is shown on LCD display.
Follow the ‘Emergency door release’
instructions in (section 03).
Turn off the water supply to the machine
and ensure that the coin trap cover is
correctly fitted and that the plug is closed,
(see section 02).
Adjust the feet until the machine is level,
(see section 03).
Check the drainage hose is draining
into a suitable place (drain, sink or
standpipe), (see section 02).
Ensure the hoses are fitted correctly,
(see section 02).
Close the soap tray.
Remove soap tray and clean((
Adjust feet until the machine is level,
(see section 02).
Return the Rollerjack
TM
handle carefully
to its position under the machine,
(see section 01).
Remove top, rear and front packaging,
(see section 01).
Call Dyson helpline.
Check orientation of hot and cold pipes.
4
4
5
5
5
5
10
10
9
LCD display is blank
Certain spin speeds, temperatures or
soil types cannot be selected
Cannot open outer door
Machine leaks water
Machine shakes during the cycle
Burning smell
Clothes warm at end of cycle
There is no power to the
machine.
There are limits set on these options for
each programme to prevent unsuitable
options being selected.
Machine has not finished the cycle.
Machine has paused and the water level
is too high or the water is too hot.
Child lock is active.
Power cut or any other cause not listed
above.
Coin trap cover is not in place, or the
plug is not closed.
Machine is not level.
Drainage hose is not connected correctly.
Inlet hoses are not positioned or
correctly fitted.
Soap tray is open.
Soap tray is blocked with detergent
2 adjustable front feet are not level.
Rollerjack
TM
handle has not been replaced
under the machine.
Transit packaging not removed.
Transit packaging is removed
Hot and cold pipes reversed.
11 02Troubleshooting
Symptom
Some solutions may require you to disconnect the electricity and water supply.
Possible causes
Solutions
Remove soap tray and clean (see section 01).
10
8887_CRO2_OPS_INNERS.qxd 5/11/03 3:28 pm Page 20