Cissell IPSO RI 800-16 Iron User Manual


 
_________________________________________________________________________________________
Rotary ironer RI800-16 Technical data for customer service 04/2005
The closing of the ironingplate does not function
when the footswitch is activated.
1. Rocker switch on “0“
2. The electrical connection is interrupted
3. Microswitch in footswitch defect
4. Check connection of the cable in the
footswitch and the rollerhead.
5. Motor in ironing plate defect
6. Gearwheel drive defect
7. Lever on the pressure arm defect
Roller rotates even when the footswitch is not
activated.
1. Microswitch on the pressure arm defect
2. Footswitch defect
3. Printed circuit board defect
The ironingplate rests against the roll when the
footswitch is not activated.
1. Spring on the pressure arm is defect