Asko TL751XXL Clothes Dryer User Manual


 
33
Customer Care Center
1-800-898-1879
www.askousa.com
Electrical requirements
3-wire connection : Direct wire
Grounding through
the neutral conductor
is prohibited for (1)
new branch-circuit
installations, (2)
mobile homes, (3)
recreational vehicles, and (4)areas where
local codes prohibit grounding through the
neutral conductor.
Prepare minimum 5 ft (1.52 m) of length in
order for dryer to be replaced.
First, strip 3 1/2” (8.9 cm) of outer sheath
from end and strip 1” of insulation from each
conductor.
Then, put the hooked shape end of the wire
under the screw of the terminal block (hooked
end facing rightward) and pinch the hook
together and tighten the screw securely.
1. Connect neutral wire (white) of power cord
to center terminal block screw.
2. Connect red and black wires to the left and
right terminal block screws.
3. Make sure that the strain relief screw is
tightened.
Be sure that all terminal block nuts are on
tight and power cord is in the correct position.
Important!