Electrical requirements
4-wire connection: Direct wire
Grounding through
the neutral
conductor is
prohibited for (1)
new branch-circuit
installations, (2)
mobile homes, (3) recreational vehicles, and
(4) areas where local codes prohibit
grounding through the neutral conductor.
Prepare minimum 5 ft (1.52 m) of length in
order for dryer to be replaced.
First, peel 5” (12.7 cm) of covering material
from end. Strip 5 inches of ground wire
insulation. After cutting 1 1/2” (3.8 cm) from 3
other wires peel insulation back 1” (2.5 cm).
Make ends of 3 wires a hook shape.
Then, put the hooked shape end of the wire
under the screw of the terminal block (hooked
end facing
rightward) and pinch the hook together and
tighten the screw securely.
1. Connect neutral wire (white) of power cord
to center terminal block screw.
2. Connect red and black wires to the left and
right terminal block screws.
3. Make sure that the strain relief screw is
tightened.
Be sure that all terminal block nuts are on
tight and power cord is in the correct position.