14 Maytag Co. 113413-11
Gas Specifications for Non-CE Approved Dryers***
Gas Type and
Nominal Heating Value
Supply
Pressure
**Gross
Heat Input
Orifice Size
**Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
in WC Btu/hr kW DMS mm in WC
Natural 1,000 7.0-13.0 55,000
16.12
20
4.089
13.0
*Liquid Propane 2,500 11.0 55,000
16.12
44
2.184
1 10.0
Heat Input/Gas Consumption/Orifice (Injector) Data (For Non-CE [European] Models Only)
Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.
** Information is per pocket/tumbler.
*** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.
** Information is per pocket/tumbler.
*** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)
NOTES _____________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
Gas Specifications for CE Approved Dryers***
Gas Type and
Nominal Heating Value
Supply
Pressure
**Gross
Heat Input
**Fuel
Consumption
Orifice Size
**Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
mb Btu/hr kW DMS mm mb
Natural (I
2H
/I
2E
) 1,000
15-30
55,000
16.12 1.557 M
3
/H
22
3.988
1
6.9
Natural (I
2L
) 830
20-35
55,000
16.12 1.876 M
3
/H
22
3.988
1
9.5
Natural (I
2ELL
) 830
15-30
55,000
16.12 1.876 M
3
/H
22
3.988
1
9.5
*Natural (I
2E+
)
1,000
20
55,000
16.12 1.557 M
3
/H
31
3.048
1
830
25
55,000
16.12 1.876 M
3
/H
31
3.048
1
*Butane (I
3+
)3,175
28-30
55,000
16.12 1.162 kg/H
48
1.930
1
*Propane (I
3+
)2,500
37
55,000
16.12 1.162 kg/H
48
1.930
1
Butane (I
3B/P
)3,175
28-30/50
55,000
16.12 1.162 kg/H
44
2.184
1
18.1
Propane (I
3P
)2,500
28-30/50
55,000
16.12 1.162 kg/H
44
2.184
1
24.9