American Dryer Corp. MLG33 Clothes Dryer User Manual


 
113413-11 Maytag Co. 13
!
!
!
!
!
Warning
Fire or explosion could result due to failure of
isolating or disconnecting the gas supply as noted.
Note
Undersized gas piping will result in ignition
problems, slow drying, increased use of energy,
and can create a safety hazard.
The dryer must be connected to the type of heat/gas indicated
on the data label and pressure must be confirmed. If this
information does not agree with the type of gas available, do
not operate the dryer. Contact the distributor who sold the
dryer or contact the manufacturer.
The input ratings shown on the data label are for elevations
up to 2,000 feet (610 meters), unless elevation requirements
of over 2,000 feet (610 meters) were specified at the time the
dryer order was placed with the factory. The adjustment or
conversion of dryers in the field for elevations over 2,000 feet
(610 meters) is made by changing each burner orifice. If this
conversion is necessary, contact the distributor who sold the
dryer or contact the manufacturer.
Important
If connection to this appliance is made with a
flexible hose, it must be suitable for the appliance
category in accordance with national installation
regulations of the country of destination, and if in doubt the
installer must contact the supplier. The manufacturer of
this appliance does not recommend the use of flexible gas
supply line/hose. An external gas supply shutoff must be
provided.
CE Dryers
There are 2 N.P.T. to B.S.P.T. adaptors included with each
dryer, which must be installed to the gas inlets. The adaptors
are shipped in the upper tumbler.
Important
Pipe joint compounds that resist the action of
natural, propane, and butane gases must be used.
Warning (CE Dryers Only)
This appliance must only be operated with the gas
type indicated on the dryer’s data plate. If the
appliance is converted (gas type changed), a data plate
amendment must be obtained from Maytag Co. for CE
approved units.
Gas Connections
Inlet connection .......... 1/2” N.P.T. (non-CE dryers)
3/8” B.S.P.T. (CE dryers)
Inlet supply size ......... 1/2” Diameter Pipe (minimum)
NOTES ____________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________