American Dryer Corp. ML-55HS Clothes Dryer User Manual


 
51
IMPORT ANT
MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR PHASE 6 MODELS
(ELECTRIC OR STEAM MODELS ONLY)
This dryer was manufactured with a manual reset basket (tumbler)/lint chamber hi-limit thermostat which is
monitored by the Phase 6 computer. If the manual reset thermostat is open prior to start of the drying cycle, the
dryer will start momentarily and then shut down, displaying “dRUM SAFETY FAIL” with an audio indication.
If the manual reset hi-limit thermostat opens during a drying cycle, the display will read “dRUM SAFETY FAIL”
with an audio indication. If the drum temperature is above 100º F (38º C), the dryer will continue to run with no
heat for 3 minutes or until the drum temperature has flattened below 100º F (38º C). The CLEAR/STOP button
on the Phase 6 keyboard (touch pad) must be pressed to clear this “dRUM SAFETY FAIL” condition. The
open manual reset hi-limit thermostat must be reset “manually” prior to the start of the next cycle.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner operation.
The basket (tumbler) manual reset hi-limit is locked in the chamber area.
WARNING: Discontinue power to dryer before attempting to reset hi-limit.
IMPORTANT
This dryer is equipped with a lint
chamber hi-limit thermostat which must
be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.
ADC P/N: 114501