SECTION VI
ROUTINE MAINTENANCE
A. CLEANING
A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from
various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be
determined from experience at each location. Maximum operating efficiency is dependent upon proper air
circulation. The accumulation of lint can restrict this airflow. If the guidelines in this section are met, an ADC
dryer will provide many years of efficient, trouble free, and most importantly safe operation.
WARNING: LINT FROM MOST FABRICS IS HIGHLY COMBUSTIBLE. THE
ACCUMULATION OF LINT CAN CREATE A POTENTIAL FIRE HAZARD.
WARNING: KEEP DRYER AREA CLEAR and FREE FROM COMBUSTIBLE
MATERIALS, GASOLINE, and OTHER FLAMMABLE VAPORS and
LIQUIDS.
NOTE: Suggested time intervals shown are for average usage which is considered six (6) to eight (8)
operational (running) hours per day.
SUGGESTED CLEANING SCHEDULE
EVERY SECOND or THIRD LOAD
Clean the lint screen every second or third load. A clogged lint screen will cause poor dryer performance. The
lint screen is located behind the lint door in the base of the dryer. Open the lint door, brush the lint off the lint
screen, and remove the lint. Inspect lint screen and replace if torn.
NOTE: The frequency of cleaning the lint screen can best be determined from experience at each
location.
WEEKLY
Clean lint accumulation from lint chamber, thermostat, and microprocessor temperature sensor (sensor bracket)
area.
WARNING: TO AVOID THE HAZARD OF ELECTRICAL SHOCK, DISCONTINUE
ELECTRICAL SUPPLY TO THE DRYER.
STEAM MODELS - clean the steam coil fins. We suggest using compressed air and a vacuum cleaner with
brush attachment.
WARNING: When cleaning steam coil fins, be careful not to bend the fins. If fins are bent, straighten
by using a fin comb, which is available from local air conditioning supply house.