American Dryer Corp. ML-55HS Clothes Dryer User Manual


 
26
2. Technical Gas Data
a. Gas Specifications
b. Gas Connections:
Inlet connection ------------ 1/2-inch N.P.T.
Inlet supply size ------------ 1/2-inch N.P.T. (minimum)
Btu/hr input (per dryer) ----160,000 (40,320 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must
be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas
valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator
or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source
(L.P. tank) or an external regulator must be added to each dryer.
TYPE OF GAS
L.P.
Conversion Kit
Part Number
ADC
MODEL
NUMBER
BTU
Per Hour
Rating
kcal/hr
Rating
Natural Liquid Propane
Qty. D.M.S.*
Part
Number
Qty. D.M.S.*
Part
Number
MLG-55 160,000 40,320 3 #29 140820 3 #48 140804 881598
Shaded area is stated in metric equivalent
* Drill Material Size (D.M.S.) equivalents are as follows:
Natural Gas ............... #29 = 0.1360" (3.4544 mm).
Liquid Propane Gas .. #48 = 0.0760" (1.9304 mm).
TYPE OF GAS
Natural Liquid Propane
Manifold Pressure* 3.5 inches W.C.
8.7 mb
10.5 inches W.C.
26.1 mb
Inline Pressure 6.0 - 12.0 inches W.C.
14.92 - 29.9 mb
10.5 inches W.C.
26.1 mb
Shaded areas are stated in metric equivalents
* Measured at gas valve pressure tap when the gas valve is on.