American Dryer Corp. D170 Clothes Dryer User Manual


 
113376-4 Telephone 01422 822282 17
Water Information ____________________
Before You Start
Check Local Codes and Permits
Call your local water company or the proper municipal
authority for information regarding local codes.
Important
It is your responsibility to have all plumbing
connections made by a qualified professional to
ensure that the plumbing installation is adequate and
conforms to local, state, and federal regulations or codes.
It is the installer’s or owner’s responsibility to see that the
necessary or required water, water pressure, pipe size, or
connections are provided. The manufacturer assumes no
responsibility if the fire suppression system is not connected,
installed, or maintained properly.
Installation Requirements
The fire suppression system must be supplied with a minimum
water pipe size of 1/2” and be provided with 40 psi +/- 20 psi
(2.75 bar +/- 1.37 bar) of pressure. For use of optional manual
bypass, a second source with the same piping and pressure
requirements is required.
Flexible 1/2 feeds must be provided to avoid damage to
electric water solenoid valve by vibration.
Important
Flexible supply line/coupling must be used.
Solenoid valve failure due to hard plumbing
connections will void warranty.
Typical Water Supply
!
!
!
!
!
If the rear area of the dryer or the water supply is located in
an area where it will be exposed to cold/freezing
temperatures, provisions must be made to protect these water
lines from freezing.
Warning
If the water in the supply line or water solenoid
valve freezes, the fire suppression system will be
inoperative!!
Important
Appliance is to be connected to the water mains
using a new hose set and the old hose set should
not be reused.
Water Connections
The water connection is made to the 3/4” M.P.T. hex bushing
located at the rear upper midsection of the dryer.
The water solenoid valve has a 3/8” M.P.T. connection
supplied with a 3/4” M.P.T. x 3/8” F.P.T. hex bushing to provide
the minimum 1/2-inch supply (feed) line. Flexible supply line/
coupling must be used in an effort to avoid damaging the
electric water solenoid valve.
Important
Flexible supply line/coupling must be used.
Solenoid valve failure due to hard plumbing
connections will void warranty. It is recommended that a
filter or strainer be installed in the water supply line.