American Dryer Corp. AD-540 Clothes Dryer User Manual


 
36
2. Johnson Control G760 BCD-1
a. Upon completing installation of the replacement
Direct Spark Ignition (DSI) module, reestablish
power to the dryer.
b. Start the drying cycle.
c. The module’s indicator light will then turn
“green.” The gas valve
will be energized and
the ignitor probe will spark for approximately
8 seconds. The burner flame should now be
established.
d. With the burner flame on, remove the flame
sensor wire from the sense terminal of the DSI
module.
e. The burner flame must shut off and the ignition
module will wait 30 seconds and try again and
repeat two (2) more times.
f. Now the DSI module L.E.D. (light emitting diode) indicator will light a blinking “GREEN” light
continuously...LOCKOUT mode. This indicates that the module tried to ignite the gas a total of three (3)
times of an 8-second spark each time. After the third time this blinking “GREEN” L.E.D. (light emitting
diode) comes on.
g. Functional check of the Direct Spark Ignition (DSI) Module is complete.