American Dryer Corp. AD-530HS Clothes Dryer User Manual


 
47
9. Failed microprocessor controller (computer)...temperature calibration is inaccurate.
10. Failed burner/oven hi-limit.
11. Failed basket (tumbler) hi-limit thermostat.
12. Lint accumulation in location exhaust system.
T. Condensation on main door glass...
1. Too long, undersized, or improperly installed duct work.
2. Exhaust back draft damper is stuck open or partially open.
3. Restriction in exhaust duct work.
U. Dryer is making scraping noise at basket (tumbler) area...
1. Check for object(s) caught in the basket (tumbler) wrapper area.
2. Basket (tumbler) is out of alignment ...
a. Check both the vertical alignment and lateral alignment.
b. Check gap between the front panel and the basket (tumbler) front...set screws may have come loose and
basket (tumbler) walked forwards or backwards.
3. Loose or broken basket (tumbler) tie rod.
4. Broken basket (tumbler) support.
V. Excessive noise and/or vibration...
1. Dryer is not level.
2. Impellor (fan) is out of balance or broken.
3. Loose basket (tumbler) tie rod.
4. Basket (tumbler) is out of adjustment, or adjustment bolts (hardware) are loose.
5. Loose motor or motor mount assembly.
W. Basket (tumbler) turns too fast (as opposed to other baskets [tumblers])...
1. Foreign object(s) caught between basket (tumbler) belt and motor shaft.