American Dryer Corp. AD-530HS Clothes Dryer User Manual


 
30
NOTE: The dryer can be stopped at any time by opening the main door. To restart dryer, shut the
main door and press desired setting.
4) Open main door to stop dryer, and change selection to “PERM PRESS” (medium) setting.
Repeat this procedure, but change the selection (setting) to “HIGH TEMP”. This will confirm that
the selection key circuits are functioning properly.
NOTE: Selection (setting) changes can be made at any time during the drying cycle by opening and
closing the main door and then making a new selection.
5) Repeat above procedure for other basket (tumbler).
b. OPL (NON-COIN) MODELS ONLY
1) The LED display(s) will read “FILL”, which means that the dryer is available.
2) Start the dryer by pressing the desired setting “LOW TEMP”. The LED display will now
read selection (setting) made and the drying time portion of the LED display will read ”00”
and count upwards in time.
NOTE: The dryer can be stopped at any time opening the main door. To restart the dryer, shut the main
door and press the desired setting.
3) Open main door to stop the dryer, and change selection to “PERM PRESS” (medium) setting.
Repeat this procedure, but change the selection (setting) to “HIGH TEMP”. This will confirm
that the selection key circuits and door switch circuits are functioning properly.
NOTE: Selection (setting) changes can be made at any time during the drying cycle by opening and closing
the main door and then making a new selection.
4) Repeat above procedure for the other basket (tumbler).
3. Heat Circuit Operational Test
a. GAS MODELS
When a gas dryer is first started (during the initial start-up), it has a tendency not to ignite on the first
attempt. This is because the gas supply piping is filled with air. It may take a few minutes for this air to
be purged from the lines.