American Dryer Corp. AD-410 Clothes Dryer User Manual


 
53
The tilting system in the dryer, whether it is 1-way tilt or
2-way tilt, is controlled by the TSX-07 programmable logic
controller (PLC). The PLC will determine if the dryer is safe
to tilt based on inputs from several sources. If ALL conditions
are met, the PLC will send a signal to the tilt relays, which
energize the appropriate tilt solenoid valve. Compressed air
is then allowed to enter the cylinders raising the basket
(tumbler).
F. TILTING SYSTEM DESCRIPTION