American Dryer Corp. AD-27 Clothes Dryer User Manual


 
34
SECTION VII
ELECTRICAL SERVICE SPECIFICATIONS
NOTE: Contact the factory for electrical information not listed.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
ADG-27 (Gas)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME.
When ordering, specify exact voltage.
NOTES: A. Fuse ratings are dual element time delay current limiting, class
RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY.
For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
C.
Circuit breakers for 3Ø dryers must be 3-pole type.
Service
Voltage
Phase
Wire
Service
Approx.
Amp
Draw
Fusing
Dual Element
Time Delay
Circuit
Breaker
115 2 9.6 --- 20
208 2 5.0 --- 15
230/240 2 5.3 --- 15
208 3 3.0 --- 15
230/240 3 3.2 3.6 15
460 3/4 2.1 2.5 15