3. Grounding
A ground (earth) connection must be provided and installed in accordance with state and local codes. In
the absence of these codes, grounding must conform to applicable requirements of the National Electrical
Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the Canadian Electrical Codes Parts 1 & 2
CSA C22.1-1990 or LATEST EDITION. The ground connection may be to a proven earth ground at the
location service panel.
For added personal safety, when possible, it is suggested that a separate ground wire (no. 18 minimum) be
connected from the ground connection of the dryer to a grounded cold water pipe. DO NOT ground to a
gas pipe or hot water pipe. The grounded cold water pipe must have metal to metal connection ALL the
way to electrical ground. If there are any nonmetallic interruptions, such as, a meter, pump, plastic, rubber,
or other insulating connectors, they must be jumped with no. 4 copper wire and securely clamped to bare
metal at both ends.
IMPORTANT: For personal safety and proper operation, the dryer must be grounded.
4. Electrical Connections
A wire diagram is located inside the control box for connection data.
a. GAS DRYERS ONLY - Single-Phase (1Ø) Hookup
The electrical connections on ALL single-phase (1Ø) dryers are made into the rear service box located
at the upper left of the dryer.