American Dryer Corp. AD-170 Clothes Dryer User Manual


 
58
HOW TO USE A MANOMETER
1.With dryer in non-operating mode, remove plug on the gas valve pressure tap.
2.Attach plastic tubing to pressure tap. Fitting is supplied with manometer (see illustration).
3.Attach manometer to dryer using magnet.
NOTE: Place manometer in a position so that readings can be taken at eye level.
C. Using a Manometer
4. Fill manometer with water, as shown in illustration,
to the zero level.
5. Start dryer. With burner on, take a reading.
A. Read water level at the inner tube.
Readings should be taken at eye level.
B. Correct readings should be:
NATURAL GAS: 3.5 - 4.0 inches W.C.
L.P. GAS: 11 - 10.5 inches W.C.
6. If water column pressure is incorrect refer to
"TO ADJUST GAS PRESSURE"
7. Reverse procedure for removing manometer.