Alliance Laundry Systems P232156R9 Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Basic Installation/Operation
F232156
12
Table 3 (continued)
UWPV Models
Specifications 35 60 80 100 125 150
Cylinder Speeds / Centrifugal Force Data
1/2 Wash/reverse, RPM / g 26 / .25 26 / .31 26 / .35 26 / .35 26 / .40 23 / .31
Wash/reverse, RPM / g 42 / .66 40 / .73 40 / .82 40 / .82 37 / .82 36 / 0.8
Distribution, RPM / g 83 / 2.57 71 / 2.29 73 / 2.57 70 / 2.50 62 / 2.29 61 / 2.29
Medium extract, RPM / g 325 / 39 305 / 42 325 / 54 325 / 54 260 / 40 262 / 42
High extract l, RPM / g
*Design U6 models
474 / 84 435 / 86 408 / 85 408 / 85 380 / 86 417 / 106
533 / 106 483 / 106 456 / 106 456 / 106 N/A 417 / 106
High extract 2, RPM / g 610 / 139 555 / 140 523 / 140 523 / 140 485 / 140 512 / 160
High extract 3, RPM / g
*Design U6 models
795 / 235 720 / 235 671 / 230 601 / 184 534 / 170 573 / 200
897 / 308 813 / 300 767 / 300 767 / 300 580 / 200 701 / 300
Balance Detection
Vibration switch installed STD STD STD STD STD STD
Switch gap setting, in. (mm)** .20 (.008) NO-GO
.15 (.006) GO
.25 (.010) NO-GO
.20 (.008) GO
.25 (.010) NO-GO
.20 (.008) GO
.25 (.010) NO-GO
.20 (.008) GO
.20 (.008) NO-GO
.15 (.006) GO
.30 (.014) NO-GO
.33 (.013) GO
Direct Steam Heating (Optional)
Steam inlet connection size,
in. (mm)
1/2 (13) 1/2 (13) 1/2 (13) 1/2 (13) 3/4 (19) 3/4 (19)
Number of steam inlets 1 1 1 1 1 1
Steam required to
raise bath temperature,
10°F, lb. (10°C, kg)
LOW 2.1 (1.5) 3.3 (2.4) 4.6 (3.3) 5.7 (4.1) 6.7 (4.9) 8.3 (6.0)
MED 2.3 (1.7) 3.7 (2.6) 5.2 (3.8) 6.5 (4.7) 7.8 (5.6) 9.5 (6.9)
HIGH 2.7 (1.9) 4.1 (2.9) 6.1 (4.4) 7.6 (5.5) 9.1 (6.6) 11.1 (8.0)
Average consumption per cycle,
bhp (kg)
1.4 (21.4) 2.1 (33.4) 3.1 (48.4) 3.8 (60.4) 4.6 (72.0) 5.8 (91.0)
Electrical Heating (Optional)
Total electrical heating capacity,
kW
15.6 25.2 37.8 37.8 50.4 N/A
Number of electrical heating
elements
669912N/A
Electrical heating element size,
kW
2.6 4.2 4.2 4.2 4.2 N/A
Time required to
raise bath temperature,
10°F, min. (5°C, min.)
LOW 2.4 (3.6) 2.4 (3.7) 2.2 (3.4) 2.8 (4.2) 2.5 (3.8) N/A
MED 2.7 (4.1) 2.7 (4.1) 2.5 (3.9) 3.2 (4.8) 2.9 (4.4) N/A
HIGH 3.1 (4.7) 3.0 (4.6) 3.0 (4.5) 3.7 (5.6) 3.4 (5.1) N/A
*Refer to Figure 4 and Figure 5, and serial number decal on machine to determine design series.
** Gap setting should be made with “GO–NO-GO” type feeler gauge.
N/A = Not Applicable
Table 3