Alliance Laundry Systems P232156R9 Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Basic Installation/Operation
F232156
10
Table 2 (continued)
UWAV Pocket Hardmount General Specifications
Specifications 35 60 80 100 125
Drive Train Information
Number of motors in drive train11111
Drive motor power, hp (kW) 2.3 (1.7) 2.9 (2.2) 5.0 (3.7) 5.0 (3.7) 7.5 (5.6)
Cylinder Speeds / Centrifugal Force Data
1/2 Wash/reverse, RPM / g 26 / .25 26 / .31 26 / .35 26 / .35 26 / .40
Wash/reverse, RPM / g 42 / .66 40 / .73 40 / .82 40 / .82 37 / .82
Distribution, RPM / g 83 / 2.57 71 / 2.29 73 / 2.57 70 / 2.50 62 / 2.29
High extract 1, RPM / g 329 / 40 297 / 40 280 / 40 280 / 40 260 / 40
High extract 2, RPM / g 534 / 106 483 / 106 456 / 106 456 / 106 422 / 106
High extract 3, RPM / g 656 / 160 594 / 160 560 / 160 560 / 160 518/ 160
Balance Detection
Vibration safety switch installed N/A STD STD STD STD
Safety switch gap setting, in. (mm)*
N/A
.25 (.010) NO-GO
.20 (.008) GO
.25 (.010) NO-GO
.20 (.008) GO
.25 (.010) NO-GO
.20 (.008) GO
.20 (.008) NO-GO
.15 (.006) GO
Direct Steam Heating (Optional)
Steam inlet connection size, in. (mm) .5 (13) .5 (13) .5 (13) .5 (13) .75 (19)
Number of steam inlets 11111
Steam required to raise bath
temperature,
10°F, lb. (10°C, kg)
LOW 2.1 (1.5) 3.3 (2.4) 4.6 (3.3) 5.7 (4.1) 6.7 (4.9)
MED 2.3 (1.7) 3.7 (2.6) 5.2 (3.8) 6.5 (4.7) 7.8 (5.6)
HIGH 2.7 (1.9) 4.1 (2.9) 6.1 (4.4) 7.6 (5.5) 9.1 (6.6)
Average consumption per cycle, bhp
(kg)
1.4 (21.4) 2.1 (33.4) 3.1 (48.4) 3.8 (60.4) 4.6 (72.0)
Electrical Heating (Optional)
Total electrical heating capacity, kW 15.6 25.2 37.8 37.8 50.4
Number of electrical heating elements669912
Electrical heating element size, kW 2.6 4.2 4.2 4.2 4.2
Time required to raise bath
temperature,
10°F, min. (10°C, min.)
LOW 2.4 (3.6) 2.4 (3.7) 2.2 (3.4) 2.8 (4.2) 2.5 (3.8)
MED 2.7 (4.1) 2.7 (4.1) 2.5 (3.9) 3.2 (4.8) 2.9 (4.4)
HIGH 3.1 (4.7) 3.0 (4.6) 3.0 (4.5) 3.7 (5.6) 3.4 (5.1)
* Gap setting should be made with “GO/NO-GO” type feeler gauge.
Table 2