42
K. PROGRAM LOCATION 08 (PL08)
Perm Press Cool Down Temperature/Time
Location to be viewed/changed.
Press “Perm Press” key.
Display will read “PPCd,” “Perm Press”
key cool down status for 3-seconds and
then cool down temperature and time
programmed. If no changes, press “Perm
Press” key twice. Otherwise, press “HI”
or “LO” keys and then “Perm Press” key.
Summary: Cool down temperature is programmable from a minimum of 70° F to a maximum of 190° F in
ten-degree increments or from a minimum 21° C to a maximum of 88° C in five-degree increments.
For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a
minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C
to a maximum of 77° C in five-degree increments.
For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable
from a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of
38° C to a maximum of 71° C in five-degree increments.
Cool down is programmable from 0 to 9 minutes.
PL08
PPCd
Perm Press
·100·3 HI Temp
Perm Press
LO Temp
Refer to
Section V
for instructions
on entering program locations.
(Wait 3-Seconds)
Continued from J.
100·3LO Temp HI Temp
Perm Press
PL09
Proceed to next location
to be changed
To exit program mode,
open program switch
Temperature Decrease
Temperature Increase
Time Decrease Time Increase