ADC AD-26 Clothes Dryer User Manual


 
22
PL04 - HIGH COOL DOWN TEMPERATURE/TIME (HICd)
The first part of this program controls the cool down temperature when the Phase 5 microprocessor controller
(computer) is used in the automatic mode. The cool down temperature is programmable from a minimum of
70° F to a maximum of 190° F in ten-degree increments or from a minimum 21° C to a maximum of 88° C in
five-degree increments.
For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a minimum of
100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to a maximum of 77° C
in five-degree increments.
For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable from a minimum
of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C to a maximum of 71°
C in five-degree increments.
The second part of this program controls the cool down time for both the automatic and timed modes. The cool
down time can be programmed from a minimum of 0 to a maximum of 9 minutes.
NOTE: When the Phase 5 microprocessor controller (computer) is used in the automatic mode, at the
end of the drying cycle, the Phase 5 microprocessor controller (computer) will start the cooling
cycle for the cool down time programmed or until the temperature has dropped to the
programmed cool down temperature, whichever of the two (2) comes first.
PL05 - LOW TEMPERATURE (LO°F)
Same as PL03 but for Low Temperature program.
PL06 - LOW COOL DOWN TEMPERATURE/TIME (LOCd)
Same as for PL04 but for Low Cool Down Temperature/Time.
PL07 - PERMANENT PRESS (PP°F)
Same as PL03 but for Permanent Press.
PL08 - PERMANENT PRESS COOL DOWN TEMPERATURE/TIME (PPCd)
Same as PL04 but for Permanent Press Cool Down Temperature/Time.
PL09 - LEFT COIN SLOT DENOMINATION (LCdE)
In the case of a single coin acceptor, this program setting is determined by the value of the coin acceptor
(i.e., 25¢).
When a dual coin acceptor is used, the program setting is determined by the left coin slot coin acceptor value
(lower coin value).
Program settings are from a minimum of 1 to a maximum of 9999.