ADC AD-26 Clothes Dryer User Manual


 
15
PL01 - TEMPERATURE CONVERSION STATUS
This program controls whether the temperature related programs will be operated in Fahrenheit (°F) or Celsius
(°C). The programs affected are:
1. Temperature Display Mode
2. Selection Cycling Temperatures
3. Cool Down Temperatures
AUTOMATIC MODE (AUtO) Patent No. 4,827,627
When this parameter (“AUtO”) is selected, the dryer will run for a preset level of dryness (PL02) or until the
programmed automatic maximum time (PL14) has expired.
At the end of the drying cycle, the dryer will go into the cool down cycle for the time period programmed (PL04,
PL06, or PL08) or until the temperature has dropped to the programmed cool down temperature (PL04,
PL06, or PL08).
NOTE: Due to humidity, atmospheric pressure, percentage of extraction, etc., the desired dryness level
may vary. It is suggested that the owner determine which level of dryness (90% to 100%) is
best suited for his/her application by experimenting with a few test loads.
NOTE: When programming, to use the Automatic Mode (“AUtO”) (Patent No. 4,827,627), the
following parameter/programs need to be checked and/or changed accordingly:
PL01 ..............................................“AUtO”
..............................................“FrEE” or “Coin” (coins required to start)
PL02 ..............................................“PdrY” (percent dry from 90% to 100%)
PL14 ..............................................“Adrt” (maximum auto dry time)
PL17 ..............................................“A” and “b” Factors
TIMED MODE (tInE)
When this parameter is selected (‘tInE”) and the Phase 5 coin microprocessor controller (computer) has been
activated, the dryer will continue to run until the preset time, including the cool down period (PL04, PL06, or
PL08), has elapsed, at which time the dryer will continue to run until the preset time, including the cool down
period (PL04, PL06, or PL08), has elapsed, at which time the dryer will cycle off or go into the optional
Anti-Wrinkle Program.