![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/a/f3/af35e263-ac64-4327-ad38-aa0a22122010/af35e263-ac64-4327-ad38-aa0a22122010-bg73.png)
Parameter Setting
107
4
Parameter Setting
Parameter Setting allow you to customize various settings to suit your needs. To
change function settings, set the Parameter Switches.
❖ Switches and Bits
Each parameter setting has a set of switches, and each of the switches consist
of eight bits, whose values are “0” or “1”. The right most bit is bit 0 and the
left most is bit 7. You can adjust the settings to match your needs by switching
the value of bits between “0” and “1”.
•Switch 02
❖ Parameter Settings List
Parameter Settings are outlined below.
00111011
↓↓↓↓↓↓↓↓
76543210
Switch Bit Item 0 1
02 0 Forwarding Mark Off On
02 3 TSI Print Off On
03 0 Automatic printing of the Memory
Transmission Result Report
Off On
03 2 Automatic Printing of the Memory
Storage Report
Off On
03 3 Whether or not to print the SEP
Code RX Reserve Report automati-
cally.
Off On
03 4 Whether or not to print the SEP
Code RX Result Report automati-
cally.
Off On
03 5 Automatic printing of the Immedi-
ate Transmission Result Report
Off On
03 7 Automatic printing of the Journal Off On
04 1 Whether or not to print the Com-
munication Failure Report and
Transfer Result Report automati-
cally.
Off On
04 4 Indicates the parties Off On
04 5 Include sender's name on reports Off On
04 7 Include a portion of the image on
reports
Off On