NI-1 BRI Provisioning
Page H-3Lucent Technologies 5ESS Switch Translations
H
Fields that must be populated on Screens 4, 5, and 6:
48. CKT TN <
enter TN
>
49. CKT LCC <
enter LCC
>
50. CKT RAX <
enter RAX value
>
55. TERMTYP <TYPEA>
56. DISPLAY <Y>
60. CSV <1>
61. CSV CHL <ANY>
63. CSV LIMIT <1>
69. CSD <2>
70. CSD CHL <ANY>
72. CSD LIMIT <2>
126. CPN SCRN <Y>
140. PIC <
enter PIC
>
The Calling Number Identification feature is assigned using the standard BRCS
preconstructed features /LICNDA and /CPCOFA. If it is possible, request
/CPCPFA for the Calling Number Identification feature, as it provides a clearer
display of the CPN information.
The Redirecting Number Delivery (RND) feature is assigned using the
preconstructed RND feature, /RND. These features are assigned to the user in