To adjust the b_ setting:
1. Light burner and set control knob for low flame.
2. Remove control knob from valve stem.
CAUTION:
Never use a metal blade to pry knob off. If knob cannot be easily removed,
tuck the folds of a cloth dishtowel under the knob skirt and pull the towel
upward with steady, even pressure.
3. Insert a slender, thin-blade screwdriver
into the recess at center of valve stem
and engage blade with slot in adjusting
screw.
4. Turn center stem adjusting screw slightly
to set flame size. Note; Turn clockwise
to reduce or counterclockwise to in-
crease flame size.
5. Replace control knob when adjustment
is completed.
COUNTERCLOCKWISE
TO INCREASE FLAME
SIZE
FLAME SIZE _'C_ J'_'
VALVE
STEM --
/
Proper adjustment will produce a stable, steady blue flame of minimum size. The
final adjustment should be checked by turning knob from Ni to Lo several times
without extinguishing the flame.
This adjustment, at the Lo setting, will automatically provide the proper flame size
at Med setting.
11