Speed Queen JC50CE Clothes Dryer User Manual


 
58
M412616
Quarterly
6. Remove screws holding rear drive guard to back
of tumbler.
7. Inspect belts for wear and proper tension (refer to
Adjustments section).
8. Reinstall rear drive guard to back of tumbler.
9. Energize electrical circuit to tumbler by turning on
electrical disconnect switch on rear of tumbler.
10. Turn on gas supply at manual gas shut off valve
in gas supply line (gas models only). Handle of
gas shut off valve should be parallel with gas
supply line when in ON position.
1. Deactivate electrical circuit by turning off
disconnect switch on rear of tumbler.
2. Perform daily cleaning of accumulated lint.
3. Perform monthly inspection and cleaning of
accumulated lint.
4. Clean accumulated lint and other debris from
front and back motor air vents.
5. Shut off gas supply at manual gas shut off valve
in gas supply line (gas models only). Handle of
gas shut off valve should be at 90
0
angle to gas
supply line when in OFF position.
Biannually
1. Deactivate electrical circuit by turning off
disconnect switch on rear of tumbler.
2. Perform daily cleaning of accumulated lint.
3. Perform monthly inspection and cleaning of
accumulated lint.
4. Perform quarterly inspection and cleaning of
accumulated lint.
5. Remove or open all panels and check accessible
bolts, nuts, screws, terminals and fittings for
tightness.
6. Shut off gas supply at manual gas shut off valve
in gas supply line (gas models only). Handle of
gas shut off valve should be at 90
0
angle to gas
supply line when in OFF position.
7. Unlock and open service panel and inspect gas
connections for evidence of leakage or loose
connections.
NOTE: Spraying a mild solution of soap and water
on joints will cause bubbles to appear on any
leaking connections.
8. Close and securely lock service panel.
9. Open electrical junction box cover and inspect all
electrical and grounding connections for security.
Tighten any loose electrical connections.
10. Close electrical junction box cover and energize
electrical circuit to tumbler by turning on electrical
disconnect switch.
11. Turn on gas supply at manual gas shut off valve
in gas supply line (gas models only). Handle of
gas shut off valve should be parallel with gas
supply line when in ON position.