Speed Queen JC50CE Clothes Dryer User Manual


 
37
M412616
30 Pound (13 kg) Tumblers
LOW STEAM DRYING TUMBLERS
GROUNDING INSTRUCTIONS
Drying tumbler must be grounded. In event of malfunction or breakdown, grounding will reduce risk of electric
shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a
grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit
conductors and connected to PE Busbar.
To reduce the risk of fire and electric shock, check with a qualified serviceman for
proper grounding procedures. Improper connection of the equipment grounding
conductor may result in a risk of electric shock.
WARNING
To reduce the risk of fire and electric shock, if electrical supply is coming from a three
phase service, DO NOT connect a Stinger Leg to a single phase machine.
WARNING
LOW PRESSURE STEAM DRYING TUMBLERS
240 V, 1 Phase 50 Hz.
Minimum Wire Size 16 AWG (1.309 mm²)
Circuit Breaker 20 AMP
Poles 2
Figure 10